  • Product description

    CJX1 series AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to1000V,rated operation current 9~475A under AC-3 duty.It is mainly used for making/breaking electric circuit at a long distance & for frequent starting/stopping & with thermal relay to com-pose a magnetic motor starter.
    The product conforms to IEC60947-4-1 standard.

    Main Technical Parameter

    Type CJX1-9
    CJX1-12
    CJX1-16
    CJX1-22
    CJX1-32 CJX1-45
    CJX1-63
    CJX1-75
    CJX1-85
    CJX1-110
    CJX1-140
    CJX1-170
    CJX1-205
    CJX1-250
    CJX1-300
    CJX1-400
    CJX1-475
    Mechanicalendurance (×106) 10 10 10 8 8 8 8 8 8
    Conventionalthermal current(A) 20 30 45 80 100 160 210 300 400/550
    Rated insulationvoltage (V) 660 660 660 1000 1000 1000 1000 1000 1000
    Rated(380V) operatingcurrent (A) AC-3 9/12 16/22 32 45/63 75/85 110/140 170/205 250/300 400/475
    AC-4 3.3/4.3 7.7/8.5 15.6 24/28 34/42 54/68 75/96 110/125 150
    Power ofcontrollablemotor(KW) AC-3 380V 4/5.5 7.5/11 15 22/30 37/45 55/75 90/110 132/160 200/250
    660V 5.5/7.5 11 23 39/55 67 100 156 235 375
    Power ofcontrollablemotor(KW) AC-4 380V 1.4/1.9 3.5/4 7.5 12/14 17/21 27/35 38/50 58/66 81
    660V 2.4/3.3 6/6.6 13 20.8/24 29.5/36 46.9/60 66/86 100/114 140
    Frequencyof operation (l/h) AC3 1000 750 750 1200/1000 1000/850 1000/750 700/500 700/500 500/420
    AC4 250 250 250 400/300 300/250 300/200 200/130 200/130 150
    Electricalendurance (×106) AC3 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2
    AC4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
    Operating voltagerange of coil (0.8~1.1)Ue
    Powerconsump-tion of coil Atracting(VA) 10 10 12.1 17 32 39 58 84 115
    Starting(VA) 68 69 101 183 330 550 910 1430 2450
    Rated insulationvoltage of auxitiarycontacts(V) 690 690 690 690 690 690 690 690 690
    Conventionalthermal current of auxitiary contacts(A) 10 10 10 10 10 10 10 10 10
    Ratedoperatingcurrent of auxitiarycontacts(A) AC15380/220 6/10 6/10 4/6 4/6 4/6 4/6 4/6 4/6 4/6
    DC13220V 0.45 0.45 0.48 0.48 0.48 0.48 0.48 0.48 0.48
    Ratedvoltage of the controlcoil(V) 50Hz 24,36,48,110,127,220,380,etc
    60Hz 24,110,220,440,etc.
    Outline & Dimensions


  •   